Gas Analyzer
  • Gas Analyzer Gas Analyzer

Gas Analyzer

MQW-511 Gas Analyzer is a device engineered for comprehensive exhaust gas analysis in gasoline vehicles. This advanced system quantifies concentrations of critical pollutants including hydrocarbons (HC), carbon monoxide (CO), carbon dioxide (CO₂), oxygen (O₂) and nitrogen oxides (NO) with the principle of non-dispersive infrared absorption method.

Send Inquiry

Product Description

1. Measure CO, HC and CO2 in motor vehicle exhaust using non dispersive infrared spectroscopy method, and measure O2 and NO using electrochemical principles. Calculate the excess air coefficient λ based on the measured values of CO, CO2, HC and O2;

2. This device is small in size, easy to operate, accurate in measurement and reliable in operation, making it suitable for OEMs, workshops and other industries.


Feature:

☞ Equipped with international level components, with small size, easy operation and accurate and reliable measurement;

☞ Equipped with automatic zero calibration function and high degree of automation;

☞ Visual design of interface, menu based operation and more convenient to use;

☞ Multi-level filtering system design can avoid contamination of sensors caused by long-term use;

☞ Communication with PC through RS-232;

☞ Exhaust emission detection during idle and two-speed idle processes on a standalone mode;

☞ Optional external or internal micro printer with direct printing function;

☞ Meets the accuracy requirements of international standard, e.g. ISO 3930 or Level I in OIML R99 .


Technical parameters:

Measurement range & Resolution

Item

HC

CO

CO2

NO

O2

Unit 

×10-6

×10-2

×10-2

×10-6

×10-2

Measurement range

0~9,999

0.00~14.00

0.00~18.00

0~5,000

0~25.00

Resolution

1

0.01

0.01

1

0.01

Indication error

Item

Measurement range

Allowable indication error

Absolute error

Relative error

HC

(0~5,000)×10-6

±12×10-6

±5%

(5,001~9,999)×10-6

/

±10%

CO

(0.00~10.00)×10-2

±0.06×10-2

±5%

(10.01~14.00)×10-2

/

±10%

CO2

(0.00~18.00)×10-2

±0.5×10-2

±5%

NO

(0~4,000)×10-6

±25×10-6

±4%

(4,001~5,000)×10-6

/

±8%

O2

(0.0~25.00)×10-2

±0.1×10-2

±5%

Other parameters

Response time

NDIR: 8s    NO:15s     O2:12s

Warm-up time

15min

Environmental condition

Air pressure

75.0kPa~110.0kPa

Temperature

-5℃~45℃

Humidity

≤95%

Power supply

AC220V±22V, 50Hz±1Hz

Consumption power

45w

Dimension (L*W*H)

240×248×410mm

Weight 

7kg